Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lasers Med Sci ; 35(2): 455-464, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31325123

RESUMO

High-level sport requires analysis of athletes' metabolic conditions in order to improve the training. Raman spectroscopy can be used to assess urinary composition advantageously when compared to conventional methods of urinalysis. In this work, Raman spectroscopy has been employed to detect creatine in urine of professional swimmers before and after training compared to sedentaries. It has been collected urine samples from five swimmers before and immediately after 150 min of swimming and submitted to Raman spectroscopy (830 nm excitation, 350 mW laser power, 20 s integration time) and compared to the urine from a control group (14 sedentary subjects). The Raman spectra of urine from four swimmers after training showed peaks related to creatine at 829, 915, 1049, and 1397 cm-1, besides peaks referred to urea, creatinine, ketone bodies, and phosphate. A spectral model estimated the concentration of creatine to be from 0.26 to 0.72 g/dL in the urine of these athletes. The presence of this metabolic biomarker in the urine of some swimmers suggests a metabolic profile influenced by the diet, supplementation, individual metabolism, and the self-response to the training. Raman spectroscopy allows a rapid and reliable detection of creatine excreted in the urine of swimming athletes, which may be used to adjust the nutrition/supplementation of each individual as well as the individual response and energy consumption depending on the type and duration of the training.


Assuntos
Atletas , Creatina/urina , Análise Espectral Raman , Natação/fisiologia , Adulto , Creatinina/urina , Feminino , Humanos , Corpos Cetônicos/urina , Masculino , Análise de Componente Principal , Comportamento Sedentário , Adulto Jovem
2.
J Photochem Photobiol B ; 185: 223-234, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29966989

RESUMO

Raman spectroscopy (RS) is a vibrational technique that is suitable for performing biochemical analyses in human tissues and fluids. This work has investigated the identification of biochemical markers due to physical performance in the urine of swimming athletes. This was achieved by means of the Raman features that were found before and after the swimming training compared to the sedentary control subjects. These particular biochemical marker identifications refer to and infer the physiological status of individuals. The urine samples (single stream) were collected before and after the training (velocity, middle distance and distance) of professional swimmers, as well as from sedentary subjects (control). The urine samples were submitted to RS (830 nm excitation, 350 mW, 400-1800 cm-1 spectral range, 4 cm-1 resolution) and the spectra after the training were compared to the spectra before training, and subsequently, to the control subjects. The principal component analysis (PCA) was employed in order to identify the biochemicals that were responsible for the spectral differences. The Raman features of the urine samples after training showed peaks that were related to common urine metabolites, such as urea and creatinine. PCA analysis also revealed Raman features that were attributed to other metabolites, such as creatine, ketone bodies, phosphate and nitrogenous compounds in the swimmers after training. RS was a rapid and reliable technique for the evaluation of urine metabolites that were related to the physical performance of high-level swimmers, which then allowed for an accurate assessment and a control of their physiological efficiencies.


Assuntos
Biomarcadores/urina , Natação , Adolescente , Atletas , Creatinina/urina , Feminino , Humanos , Corpos Cetônicos/química , Masculino , Análise de Componente Principal , Análise Espectral Raman , Ureia/urina , Adulto Jovem
3.
J Photochem Photobiol B ; 176: 92-99, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28968523

RESUMO

Raman spectroscopy is a rapid and non-destructive technique suitable for biological fluids analysis. In this work, dispersive Raman spectroscopy has been employed as a rapid and nondestructive technique to detect the metabolites in urine of physically active subjects before and after vigorous 30min pedaling or running compared to sedentary subjects. For so, urine samples from 9 subjects were obtained before and immediately after physical activities and submitted to Raman spectroscopy (830nm excitation, 250mW laser power, 20s integration time) and compared to urine from 5 sedentary subjects. The Raman spectra of urine from sedentary showed peaks related to urea, creatinine, ketone bodies, phosphate and other nitrogenous compounds. These metabolic biomarkers presented peaks with different intensities in the urine of physically active individuals after exercises compared to before, measured by the intensity of selected peaks the Raman spectra, which means different concentrations after training. These peaks presented different intensity values for each subject before physical activity, also behaving differently compared to the post-training: some subjects presented increase while others decrease the intensity. Raman spectroscopy may allow the development of a rapid and non-destructive test for metabolic evaluation of the physical training in active and trained subjects using urine samples, allowing nutrition adjustment with the sport's performance.


Assuntos
Análise Espectral Raman , Urina/química , Adulto , Creatinina/química , Creatinina/urina , Exercício Físico , Feminino , Humanos , Masculino , Fosfatos/química , Fosfatos/urina , Análise de Componente Principal , Ureia/química , Ureia/urina , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...